Export limit exceeded: 419215 CVEs match your query. Please refine your search to export 10,000 CVEs or fewer.
Export limit exceeded: 419215 CVEs match your query. Please refine your search to export 10,000 CVEs or fewer.
Export limit exceeded: 419215 CVEs match your query. Please refine your search to export 10,000 CVEs or fewer.
Export limit exceeded: 419215 CVEs match your query. Please refine your search to export 10,000 CVEs or fewer.
Export limit exceeded: 108443 CVEs match your query. Please refine your search to export 10,000 CVEs or fewer.
Search
Search Results (108443 CVEs found)
| CVE | Vendors | Products | Updated | CVSS v3.1 |
|---|---|---|---|---|
| CVE-2025-3417 | 2026-04-15 | 8.8 High | ||
| The Embedder plugin for WordPress is vulnerable to unauthorized modification of data that can lead to privilege escalation due to a missing capability check on the ajax_set_global_option() function in versions 1.3 to 1.3.5. This makes it possible for authenticated attackers, with Subscriber-level access and above, to update arbitrary options on the WordPress site. This can be leveraged to update the default role for registration to administrator and enable user registration for attackers to gain administrative user access to a vulnerable site. | ||||
| CVE-2013-3307 | 1 Linksys | 2 E1000, E1200 | 2026-04-15 | 8.3 High |
| Linksys E1000 devices through 2.1.02, E1200 devices before 2.0.05, and E3200 devices through 1.0.04 allow OS command injection via shell metacharacters in the apply.cgi ping_ip parameter on TCP port 52000. | ||||
| CVE-2015-10123 | 1 Wago | 10 750-352 Firmware, 750-829 Firmware, 750-831 Firmware and 7 more | 2026-04-15 | 8.8 High |
| An unautheticated remote attacker could send specifically crafted packets to a affected device. If an authenticated user then views that data in a specific page of the web-based management a buffer overflow will be triggered to gain full access of the device. | ||||
| CVE-2017-20213 | 1 Flir | 1 Thermal Camera | 2026-04-15 | 7.5 High |
| FLIR Thermal Camera F/FC/PT/D Stream firmware version 8.0.0.64 contains an unauthenticated vulnerability that allows remote attackers to access live camera streams without credentials. Attackers can exploit the vulnerability to view unauthorized thermal camera video feeds across multiple camera series without requiring any authentication. | ||||
| CVE-2025-23010 | 1 Sonicwall | 1 Netextender | 2026-04-15 | 7.2 High |
| An Improper Link Resolution Before File Access ('Link Following') vulnerability in SonicWall NetExtender Windows (32 and 64 bit) client which allows an attacker to manipulate file paths. | ||||
| CVE-2025-23276 | 1 Nvidia | 1 Gpu Display Driver | 2026-04-15 | 7.8 High |
| NVIDIA Installer for Windows contains a vulnerability where an attacker may be able to escalate privileges. A successful exploit of this vulnerability may lead to escalation of privileges, denial of service, code execution, information disclosure and data tampering. | ||||
| CVE-2025-23294 | 1 Nvidia | 1 Webdataset | 2026-04-15 | 7.8 High |
| NVIDIA WebDataset for all platforms contains a vulnerability where an attacker could execute arbitrary code with elevated permissions. A successful exploit of this vulnerability might lead to escalation of privileges, data tampering, information disclosure, and denial of service. | ||||
| CVE-2025-23386 | 2026-04-15 | 7.8 High | ||
| A Incorrect Default Permissions vulnerability in the openSUSE Tumbleweed package gerbera allows the service user gerbera to escalate to root.,This issue affects gerbera on openSUSE Tumbleweed before 2.5.0-1.1. | ||||
| CVE-2017-20197 | 2026-04-15 | 7.3 High | ||
| A vulnerability was found in propanetank Roommate-Bill-Tracking up to 288437f658fc9ee7d4b92a9da12557024d8bc55c. It has been declared as critical. This vulnerability affects unknown code of the file /includes/login.php. The manipulation of the argument Username leads to sql injection. The attack can be initiated remotely. The name of the patch is b32bb1b940f82d38fb9310cd66ebe349e20a1d0a. It is recommended to apply a patch to fix this issue. | ||||
| CVE-2025-42951 | 1 Sap | 1 Business One | 2026-04-15 | 8.8 High |
| Due to broken authorization, SAP Business One (SLD) allows an authenticated attacker to gain administrator privileges of a database by invoking the corresponding API.�As a result , it has a high impact on the confidentiality, integrity, and availability of the application. | ||||
| CVE-2025-40761 | 1 Siemens | 11 Ruggedcom Rox Mx5000, Ruggedcom Rox Mx5000re, Ruggedcom Rox Rx1400 and 8 more | 2026-04-15 | 7.6 High |
| A vulnerability has been identified in RUGGEDCOM ROX MX5000 (All versions), RUGGEDCOM ROX MX5000RE (All versions), RUGGEDCOM ROX RX1400 (All versions), RUGGEDCOM ROX RX1500 (All versions), RUGGEDCOM ROX RX1501 (All versions), RUGGEDCOM ROX RX1510 (All versions), RUGGEDCOM ROX RX1511 (All versions), RUGGEDCOM ROX RX1512 (All versions), RUGGEDCOM ROX RX1524 (All versions), RUGGEDCOM ROX RX1536 (All versions), RUGGEDCOM ROX RX5000 (All versions). Affected devices do not properly limit access through its Built-In-Self-Test (BIST) mode. This could allow an attacker with physical access to the serial interface to bypass authentication and get access to a root shell on the device. | ||||
| CVE-2025-40743 | 1 Siemens | 4 Sinumerik 828d, Sinumerik 840d Sl, Sinumerik Mc and 1 more | 2026-04-15 | 8.3 High |
| A vulnerability has been identified in SINUMERIK 828D PPU.4 (All versions < V4.95 SP5), SINUMERIK 828D PPU.5 (All versions < V5.25 SP1), SINUMERIK 840D sl (All versions < V4.95 SP5), SINUMERIK MC (All versions < V1.25 SP1), SINUMERIK MC V1.15 (All versions < V1.15 SP5), SINUMERIK ONE (All versions < V6.25 SP1), SINUMERIK ONE V6.15 (All versions < V6.15 SP5). The affected application improperly validates authentication for its VNC access service, allowing access with insufficient password verification. This could allow an attacker to gain unauthorized remote access and potentially compromise system confidentiality, integrity, or availability. | ||||
| CVE-2017-20215 | 1 Flir | 1 Thermal Camera | 2026-04-15 | 8.8 High |
| FLIR Thermal Camera FC-S/PT firmware version 8.0.0.64 contains an authenticated OS command injection vulnerability that allows attackers to execute shell commands with root privileges. Authenticated attackers can inject arbitrary shell commands through unvalidated input parameters to gain complete control of the thermal camera system. | ||||
| CVE-2017-20214 | 1 Flir | 1 Thermal Camera | 2026-04-15 | 7.5 High |
| FLIR Thermal Camera F/FC/PT/D firmware version 8.0.0.64 contains hard-coded SSH credentials that cannot be changed through normal camera operations. Attackers can leverage these persistent, unmodifiable credentials to gain unauthorized remote access to the thermal camera system. | ||||
| CVE-2020-11926 | 1 Luvion | 1 Grand Elite 3 Connect | 2026-04-15 | 7.5 High |
| An issue was discovered in Luvion Grand Elite 3 Connect through 2020-02-25. Clients can authenticate themselves to the device using a username and password. These credentials can be obtained through an unauthenticated web request, e.g., for a JavaScript file. Also, the disclosed information includes the SSID and WPA2 key for the Wi-Fi network the device is connected to. | ||||
| CVE-2020-10370 | 2026-04-15 | 8.8 High | ||
| Certain Cypress (and Broadcom) Wireless Combo chips such as CYW43455, when a 2021-01-26 Bluetooth firmware update is not present, allow a Bluetooth outage via a "Spectra" attack. | ||||
| CVE-2019-6268 | 2 Denx, Rad | 2 U-boot, Secflow-2v Firmware | 2026-04-15 | 7.5 High |
| RAD SecFlow-2 devices with Hardware 0202, Firmware 4.1.01.63, and U-Boot 2010.12 allow URIs beginning with /.. for Directory Traversal, as demonstrated by reading /etc/shadow. | ||||
| CVE-2019-25462 | 1 Web-ofisi | 1 Rent A Car | 2026-04-15 | 8.2 High |
| Web Ofisi Rent a Car v3 contains an SQL injection vulnerability that allows unauthenticated attackers to manipulate database queries by injecting SQL code through the 'klima' parameter. Attackers can send GET requests to with malicious 'klima' values to extract sensitive database information or cause denial of service. | ||||
| CVE-2019-25446 | 1 Digit-rs | 1 Digit Centris | 2026-04-15 | 8.2 High |
| DIGIT CENTRIS ERP contains an SQL injection vulnerability that allows unauthenticated attackers to manipulate database queries by injecting SQL code through the datum1, datum2, KID, and PID parameters. Attackers can send POST requests to /korisnikinfo.php with malicious SQL syntax in these parameters to extract or modify sensitive database information. | ||||
| CVE-2019-25443 | 1 Edlangley | 1 Inventory-webapp | 2026-04-15 | 8.2 High |
| Inventory Webapp contains an SQL injection vulnerability that allows unauthenticated attackers to manipulate database queries by injecting SQL code through GET parameters. Attackers can supply malicious SQL payloads in the name, description, quantity, or cat_id parameters to add-item.php to execute arbitrary database commands. | ||||