Export limit exceeded: 108443 CVEs match your query. Please refine your search to export 10,000 CVEs or fewer.
Search
Search Results (108443 CVEs found)
| CVE | Vendors | Products | Updated | CVSS v3.1 |
|---|---|---|---|---|
| CVE-2025-24802 | 2026-04-15 | 8.6 High | ||
| Plonky2 is a SNARK implementation based on techniques from PLONK and FRI. Lookup tables, whose length is not divisible by 26 = floor(num_routed_wires / 3) always include the 0 -> 0 input-output pair. Thus a malicious prover can always prove that f(0) = 0 for any lookup table f (unless its length happens to be divisible by 26). The cause of problem is that the LookupTableGate-s are padded with zeros. A workaround from the user side is to extend the table (by repeating some entries) so that its length becomes divisible by 26. This vulnerability is fixed in 1.0.1. | ||||
| CVE-2025-29745 | 1 Emsisoft | 1 Anti-malware | 2026-04-15 | 7.5 High |
| A vulnerability affecting the scanning module in Emsisoft Anti-Malware prior to 2024.12 allows attackers on a remote server to obtain Net-NTLMv2 hash information via a specially created A2S (Emsisoft Custom Scan) extension file. | ||||
| CVE-2025-24811 | 2026-04-15 | 7.5 High | ||
| A vulnerability has been identified in SIMATIC S7-1200 CPU 1211C AC/DC/Rly (6ES7211-1BE40-0XB0), SIMATIC S7-1200 CPU 1211C DC/DC/DC (6ES7211-1AE40-0XB0), SIMATIC S7-1200 CPU 1211C DC/DC/Rly (6ES7211-1HE40-0XB0), SIMATIC S7-1200 CPU 1212C AC/DC/Rly (6ES7212-1BE40-0XB0), SIMATIC S7-1200 CPU 1212C DC/DC/DC (6ES7212-1AE40-0XB0), SIMATIC S7-1200 CPU 1212C DC/DC/Rly (6ES7212-1HE40-0XB0), SIMATIC S7-1200 CPU 1212FC DC/DC/DC (6ES7212-1AF40-0XB0), SIMATIC S7-1200 CPU 1212FC DC/DC/Rly (6ES7212-1HF40-0XB0), SIMATIC S7-1200 CPU 1214C AC/DC/Rly (6ES7214-1BG40-0XB0), SIMATIC S7-1200 CPU 1214C DC/DC/DC (6ES7214-1AG40-0XB0), SIMATIC S7-1200 CPU 1214C DC/DC/Rly (6ES7214-1HG40-0XB0), SIMATIC S7-1200 CPU 1214FC DC/DC/DC (6ES7214-1AF40-0XB0), SIMATIC S7-1200 CPU 1214FC DC/DC/Rly (6ES7214-1HF40-0XB0), SIMATIC S7-1200 CPU 1215C AC/DC/Rly (6ES7215-1BG40-0XB0), SIMATIC S7-1200 CPU 1215C DC/DC/DC (6ES7215-1AG40-0XB0), SIMATIC S7-1200 CPU 1215C DC/DC/Rly (6ES7215-1HG40-0XB0), SIMATIC S7-1200 CPU 1215FC DC/DC/DC (6ES7215-1AF40-0XB0), SIMATIC S7-1200 CPU 1215FC DC/DC/Rly (6ES7215-1HF40-0XB0), SIMATIC S7-1200 CPU 1217C DC/DC/DC (6ES7217-1AG40-0XB0), SIPLUS S7-1200 CPU 1212 AC/DC/RLY (6AG1212-1BE40-2XB0), SIPLUS S7-1200 CPU 1212 AC/DC/RLY (6AG1212-1BE40-4XB0), SIPLUS S7-1200 CPU 1212 DC/DC/RLY (6AG1212-1HE40-2XB0), SIPLUS S7-1200 CPU 1212 DC/DC/RLY (6AG1212-1HE40-4XB0), SIPLUS S7-1200 CPU 1212C DC/DC/DC (6AG1212-1AE40-2XB0), SIPLUS S7-1200 CPU 1212C DC/DC/DC (6AG1212-1AE40-4XB0), SIPLUS S7-1200 CPU 1212C DC/DC/DC RAIL (6AG2212-1AE40-1XB0), SIPLUS S7-1200 CPU 1214 AC/DC/RLY (6AG1214-1BG40-2XB0), SIPLUS S7-1200 CPU 1214 AC/DC/RLY (6AG1214-1BG40-4XB0), SIPLUS S7-1200 CPU 1214 AC/DC/RLY (6AG1214-1BG40-5XB0), SIPLUS S7-1200 CPU 1214 DC/DC/DC (6AG1214-1AG40-2XB0), SIPLUS S7-1200 CPU 1214 DC/DC/DC (6AG1214-1AG40-4XB0), SIPLUS S7-1200 CPU 1214 DC/DC/DC (6AG1214-1AG40-5XB0), SIPLUS S7-1200 CPU 1214 DC/DC/RLY (6AG1214-1HG40-2XB0), SIPLUS S7-1200 CPU 1214 DC/DC/RLY (6AG1214-1HG40-4XB0), SIPLUS S7-1200 CPU 1214 DC/DC/RLY (6AG1214-1HG40-5XB0), SIPLUS S7-1200 CPU 1214C DC/DC/DC RAIL (6AG2214-1AG40-1XB0), SIPLUS S7-1200 CPU 1214FC DC/DC/DC (6AG1214-1AF40-5XB0), SIPLUS S7-1200 CPU 1214FC DC/DC/RLY (6AG1214-1HF40-5XB0), SIPLUS S7-1200 CPU 1215 AC/DC/RLY (6AG1215-1BG40-2XB0), SIPLUS S7-1200 CPU 1215 AC/DC/RLY (6AG1215-1BG40-4XB0), SIPLUS S7-1200 CPU 1215 AC/DC/RLY (6AG1215-1BG40-5XB0), SIPLUS S7-1200 CPU 1215 DC/DC/DC (6AG1215-1AG40-2XB0), SIPLUS S7-1200 CPU 1215 DC/DC/DC (6AG1215-1AG40-4XB0), SIPLUS S7-1200 CPU 1215 DC/DC/RLY (6AG1215-1HG40-2XB0), SIPLUS S7-1200 CPU 1215 DC/DC/RLY (6AG1215-1HG40-4XB0), SIPLUS S7-1200 CPU 1215 DC/DC/RLY (6AG1215-1HG40-5XB0), SIPLUS S7-1200 CPU 1215C DC/DC/DC (6AG1215-1AG40-5XB0), SIPLUS S7-1200 CPU 1215FC DC/DC/DC (6AG1215-1AF40-5XB0). Affected devices do not process correctly certain special crafted packets sent to port 80/tcp, which could allow an unauthenticated attacker to cause a denial of service in the device. | ||||
| CVE-2025-24846 | 2026-04-15 | 7.5 High | ||
| Authentication bypass vulnerability exists in FutureNet AS series (Industrial Routers) provided by Century Systems Co., Ltd. If this vulnerability is exploited, a remote unauthenticated attacker may obtain the device information such as MAC address by sending a specially crafted request. | ||||
| CVE-2025-24836 | 2026-04-15 | 7.1 High | ||
| With a specially crafted Python script, an attacker could send continuous startMeasurement commands over an unencrypted Bluetooth connection to the affected device. This would prevent the device from connecting to a clinician's app to take patient readings and ostensibly flood it with requests, resulting in a denial-of-service condition. | ||||
| CVE-2025-29621 | 2026-04-15 | 7.3 High | ||
| Francois Jacquet RosarioSIS v12.0.0 was discovered to contain a content spoofing vulnerability in the Theme configuration under the My Preferences module. This vulnerability allows attackers to manipulate application settings. | ||||
| CVE-2025-24849 | 2026-04-15 | 7.1 High | ||
| Lack of encryption in transit for cloud infrastructure facilitating potential for sensitive data manipulation or exposure. | ||||
| CVE-2025-32818 | 2026-04-15 | 7.5 High | ||
| A Null Pointer Dereference vulnerability in the SonicOS SSLVPN Virtual office interface allows a remote, unauthenticated attacker to crash the firewall, potentially leading to a Denial-of-Service (DoS) condition. | ||||
| CVE-2025-32978 | 1 Quest | 1 Kace Systems Management Appliance | 2026-04-15 | 7.5 High |
| Quest KACE Systems Management Appliance (SMA) 13.0.x before 13.0.385, 13.1.x before 13.1.81, 13.2.x before 13.2.183, 14.0.x before 14.0.341 (Patch 5), and 14.1.x before 14.1.101 (Patch 4) allows unauthenticated users to replace system licenses through a web interface intended for license renewal. Attackers can exploit this to replace valid licenses with expired or trial licenses, causing denial of service. | ||||
| CVE-2025-4212 | 2 Wordpress, Wpwham | 2 Wordpress, Checkout Files Upload For Woocommerce | 2026-04-15 | 7.2 High |
| The Checkout Files Upload for WooCommerce plugin for WordPress is vulnerable to Stored Cross-Site Scripting via file uploads in all versions up to, and including, 2.2.1 due to insufficient input sanitization and output escaping. This makes it possible for unauthenticated attackers to inject arbitrary web scripts in image files that will execute whenever a user accesses the injected page. | ||||
| CVE-2025-33029 | 2 Intel, Microsoft | 4 Proset, Proset/wireless, Proset/wireless Software and 1 more | 2026-04-15 | 7.4 High |
| Out-of-bounds write for some Intel(R) PROSet/Wireless WiFi Software for Windows before version 23.160 within Ring 2: Device Drivers may allow a denial of service. Unprivileged software adversary with an unauthenticated user combined with a low complexity attack may enable denial of service. This result may potentially occur via adjacent access when attack requirements are not present without special internal knowledge and requires no user interaction. The potential vulnerability may impact the confidentiality (none), integrity (none) and availability (high) of the vulnerable system, resulting in subsequent system confidentiality (none), integrity (none) and availability (high) impacts. | ||||
| CVE-2025-24868 | 2026-04-15 | 7.1 High | ||
| The User Account and Authentication service (UAA) for SAP HANA extended application services, advanced model (SAP HANA XS advanced model) allows an unauthenticated attacker to craft a malicious link, that, when clicked by a victim, redirects the browser to a malicious site due to insufficient redirect URL validation. On successful exploitation attacker can cause limited impact on confidentiality, integrity, and availability of the system. | ||||
| CVE-2025-4210 | 2026-04-15 | 7.3 High | ||
| A vulnerability classified as critical was found in Casdoor up to 1.811.0. This vulnerability affects the function HandleScim of the file controllers/scim.go of the component SCIM User Creation Endpoint. The manipulation leads to authorization bypass. The attack can be initiated remotely. Upgrading to version 1.812.0 is able to address this issue. The name of the patch is 3d12ac8dc2282369296c3386815c00a06c6a92fe. It is recommended to upgrade the affected component. | ||||
| CVE-2025-4277 | 1 Insyde | 1 Insydeh2o | 2026-04-15 | 7.5 High |
| Tcg2Smm has a vulnerability which can be used to write arbitrary memory inside SMRAM and execute arbitrary code at SMM level. | ||||
| CVE-2025-24876 | 2026-04-15 | 8.1 High | ||
| The SAP Approuter Node.js package version v16.7.1 and before is vulnerable to Authentication bypass. When trading an authorization code an attacker can steal the session of the victim by injecting malicious payload causing High impact on confidentiality and integrity of the application | ||||
| CVE-2025-41731 | 1 Jumo | 2 Varitrons300, Varitrons500 | 2026-04-15 | 7.4 High |
| A vulnerability was identified in the password generation algorithm when accessing the debug-interface. An unauthenticated local attacker with knowledge of the password generation timeframe might be able to brute force the password in a timely manner and thus gain root access to the device if the debug interface is still enabled. | ||||
| CVE-2025-41729 | 2026-04-15 | 7.5 High | ||
| An unauthenticated remote attacker can send a specially crafted Modbus read command to the device which leads to a denial of service. | ||||
| CVE-2025-41727 | 1 Beckhoff | 4 Beckhoff.device.manager.xar, Mdp Package, Twincat and 1 more | 2026-04-15 | 7.8 High |
| A local low privileged attacker can bypass the authentication of the Device Manager user interface, allowing them to perform privileged operations and gain administrator access. | ||||
| CVE-2025-41726 | 1 Beckhoff | 4 Beckhoff.device.manager.xar, Mdp Package, Twincat and 1 more | 2026-04-15 | 8.8 High |
| A low privileged remote attacker can execute arbitrary code by sending specially crafted calls to the web service of the Device Manager or locally via an API and can cause integer overflows which then may lead to arbitrary code execution within privileged processes. | ||||
| CVE-2025-41724 | 1 Sauter | 3 Ey-modulo 5 Devices, Modulo 6 Devices, Wscserver | 2026-04-15 | 7.5 High |
| An unauthenticated remote attacker can crash the wscserver by sending incomplete SOAP requests. The wscserver process will not be restarted by a watchdog and a device reboot is necessary to make it work again. | ||||