| A prototype pollution in the lib.setValue function of @syncfusion/ej2-spreadsheet v27.2.2 allows attackers to cause a Denial of Service (DoS) via supplying a crafted payload. NOTE: the Supplier disputes this because they found that the lib.setValue function is not utilized. |
| A prototype pollution in the lib function of php-date-formatter v1.3.6 allows attackers to cause a Denial of Service (DoS) via supplying a crafted payload. |
| Document Merge Service is a document template merge service providing an API to manage templates and merge them with given data. Versions 6.5.1 and prior are vulnerable to remote code execution via server-side template injection which, when executed as root, can result in full takeover of the affected system. As of time of publication, no patched version exists, nor have any known workarounds been disclosed. |
| oqs-provider is a provider for the OpenSSL 3 cryptography library that adds support for post-quantum cryptography in TLS, X.509, and S/MIME using post-quantum algorithms from liboqs. Flaws have been identified in the way oqs-provider handles lengths decoded with DECODE_UINT32 at the start of serialized hybrid (traditional + post-quantum) keys and signatures. Unchecked length values are later used for memory reads and writes; malformed input can lead to crashes or information leakage. Handling of plain/non-hybrid PQ key operation is not affected. This issue has been patched in in v0.6.1. All users are advised to upgrade. There are no workarounds for this issue. |
| Malformed BRID/HHIT records can cause `named` to terminate unexpectedly.
This issue affects BIND 9 versions 9.18.40 through 9.18.43, 9.20.13 through 9.20.17, 9.21.12 through 9.21.16, 9.18.40-S1 through 9.18.43-S1, and 9.20.13-S1 through 9.20.17-S1. |
| Under certain circumstances the iSTAR Configuration Utility (ICU) tool could have a buffer overflow issue |
| Out-Of-Bounds Read vulnerability exists in the JT file reading procedure in SOLIDWORKS eDrawings on Release SOLIDWORKS Desktop 2025. This vulnerability could allow an attacker to execute arbitrary code while opening a specially crafted JT file. |
| Longse model LBH30FE200W cameras, as well as products based on this device, make use of telnet passwords which follow a specific pattern. Once the pattern is known, brute-forcing the password becomes relatively easy.
Additionally, every camera with the same firmware version shares the same password. |
| Longse NVR (Network Video Recorder) model NVR3608PGE2W, as well as products based on this device, create a WiFi network with a default password.
A user is neither advised to change it during the installation process, nor such a need is described in the manual. As the cameras from the same kit connect automatically, it is very probable for the default password to be left unchanged. |
| Open Robotics Robotic Operating System 2 (ROS2) and Nav2 humble versions were discovered to contain a buffer overflow via the nav2_amcl process. This vulnerability is triggered via sending a crafted .yaml file. |
| Open Robotics Robotic Operating System 2 (ROS2) and Nav2 humble versions were discovered to contain a buffer overflow via the nav2_amcl process. This vulnerability is triggered via sending a crafted .yaml file. |
| UERANSIM before 3.2.6 allows out-of-bounds read when a RLS packet is sent to gNodeB with malformed PDU length. This occurs in function readOctetString in src/utils/octet_view.cpp and in function DecodeRlsMessage in src/lib/rls/rls_pdu.cpp |
| A vulnerability has been identified in JT Open (All versions < V11.5), JT2Go (All versions < V2406.0003), PLM XML SDK (All versions < V7.1.0.014), Teamcenter Visualization V14.2 (All versions < V14.2.0.13), Teamcenter Visualization V14.3 (All versions < V14.3.0.11), Teamcenter Visualization V2312 (All versions < V2312.0008), Teamcenter Visualization V2406 (All versions < V2406.0003). The affected applications contain a stack based overflow vulnerability while parsing specially crafted XML files. This could allow an attacker to execute code in the context of the current process. |
| There are multiple stack-based buffer overflow vulnerabilities in V-SFT (v6.2.2.0 and earlier), TELLUS (v4.0.19.0 and earlier), and TELLUS Lite (v4.0.19.0 and earlier).
If a user opens a specially crafted file, information may be disclosed and/or arbitrary code may be executed. |
| Airbyte is a data integration platform for ELT pipelines. Airbyte connection builder docker image is vulnerable to RCE via SSTI which allows an authenticated remote attacker to execute arbitrary code on the server as the web server user. The connection builder is used to create and test new connectors. Sensitive information, such as credentials, could be exposed if a user tested a new connector on a compromised instance. The connection builder does not have access to any data processes. This vulnerability is fixed in 0.62.2. |
| There is an Out-of-bounds read vulnerability in TELLUS (v4.0.19.0 and earlier) and TELLUS Lite (v4.0.19.0 and earlier). If a user opens a specially crafted file, information may be disclosed and/or arbitrary code may be executed. |
| A vulnerability has been identified in APOGEE PXC Series (BACnet) (All versions), APOGEE PXC Series (P2 Ethernet) (All versions), TALON TC Series (BACnet) (All versions). Affected devices contain an out-of-bounds read in the memory dump function.
This could allow an attacker with Medium (MED) or higher privileges to cause the device to enter an insecure cold start state. |
| A vulnerability has been identified in SIPROTEC 5 6MD84 (CP300) (All versions < V9.90), SIPROTEC 5 6MD85 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 6MD86 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 6MD89 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 6MD89 (CP300) V9.6x (All versions < V9.68), SIPROTEC 5 6MU85 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 7KE85 (CP300) (All versions >= V8.80 < V10.0), SIPROTEC 5 7SA82 (CP150) (All versions < V9.90), SIPROTEC 5 7SA86 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 7SA87 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 7SD82 (CP150) (All versions < V9.90), SIPROTEC 5 7SD86 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 7SD87 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 7SJ81 (CP150) (All versions < V9.90), SIPROTEC 5 7SJ82 (CP150) (All versions < V9.90), SIPROTEC 5 7SJ85 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 7SJ86 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 7SK82 (CP150) (All versions < V9.90), SIPROTEC 5 7SK85 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 7SL82 (CP150) (All versions < V9.90), SIPROTEC 5 7SL86 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 7SL87 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 7SS85 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 7ST85 (CP300) (All versions >= V8.80 < V10.0), SIPROTEC 5 7ST85 (CP300) V9.6x (All versions < V9.68), SIPROTEC 5 7ST86 (CP300) (All versions < V10.0), SIPROTEC 5 7ST86 (CP300) V9.8x (All versions < V9.83), SIPROTEC 5 7SX82 (CP150) (All versions < V9.90), SIPROTEC 5 7SX85 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 7SY82 (CP150) (All versions < V9.90), SIPROTEC 5 7UM85 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 7UT82 (CP150) (All versions < V9.90), SIPROTEC 5 7UT85 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 7UT86 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 7UT87 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 7VE85 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 7VK87 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 7VU85 (CP300) (All versions < V9.90), SIPROTEC 5 Communication Module ETH-BA-2EL (Rev.2) (All versions < V9.90), SIPROTEC 5 Communication Module ETH-BA-2EL (Rev.2) V9.6 (All versions < V9.68), SIPROTEC 5 Communication Module ETH-BA-2EL (Rev.2) V9.8 (All versions < V9.83), SIPROTEC 5 Communication Module ETH-BB-2FO (Rev. 2) (All versions < V9.90), SIPROTEC 5 Communication Module ETH-BB-2FO (Rev. 2) V9.6 (All versions < V9.68), SIPROTEC 5 Communication Module ETH-BB-2FO (Rev. 2) V9.8 (All versions < V9.83), SIPROTEC 5 Communication Module ETH-BD-2FO (All versions >= V8.80 < V9.90), SIPROTEC 5 Communication Module ETH-BD-2FO V9.6 (All versions < V9.68), SIPROTEC 5 Communication Module ETH-BD-2FO V9.8 (All versions < V9.83), SIPROTEC 5 Compact 7SX800 (CP050) (All versions >= V9.50 < V9.90). Affected devices do not properly validate SNMP GET requests. This could allow an unauthenticated, remote attacker to retrieve sensitive information of the affected devices with SNMPv2 GET requests using default credentials. |
| C/sorting/binary_insertion_sort.c in The Algorithms - C through e5dad3f has a segmentation fault for deep recursion, which may affect common use cases such as sorting an array of 50 elements. |
| A heap-buffer-overflow vulnerability has been identified in ntopng 6.2 in the Flow::dissectMDNS function. |