Search Results (243 CVEs found)

CVE Vendors Products Updated CVSS v3.1
CVE-2024-28325 1 Asus 1 Rt-n12\+ B1 2026-04-15 6.1 Medium
Asus RT-N12+ B1 router stores credentials in cleartext, which could allow local attackers to obtain unauthorized access and modify router settings.
CVE-2024-11982 1 Billion Electric 4 M100, M120n, M150 and 1 more 2026-04-15 7.2 High
Certain models of routers from Billion Electric has a Plaintext Storage of a Password vulnerability. Remote attackers with administrator privileges can access the user settings page to retrieve plaintext passwords.
CVE-2025-43005 2026-04-15 4.3 Medium
SAP GUI for Windows allows an unauthenticated attacker to exploit insecure obfuscation algorithms used by the GuiXT application to store user credentials. While this issue does not impact the Integrity or Availability of the application, it may have a Low impact on the Confidentiality of data.
CVE-2024-42496 2026-04-15 N/A
Smart-tab Android app installed April 2023 or earlier contains an issue with plaintext storage of a password. If this vulnerability is exploited, an attacker with physical access to the device may retrieve the credential information and spoof the device to access the related external service.
CVE-2024-43378 1 Nixos 1 Calamares-nixos-extensions 2026-04-15 7.8 High
calamares-nixos-extensions provides Calamares branding and modules for NixOS, a distribution of GNU/Linux. Users who installed NixOS through the graphical installer who used manual disk partitioning to create a setup where the system was booted via legacy BIOS rather than UEFI; some disk partitions are encrypted; but the partitions containing either `/` or `/boot` are unencrypted; have their LUKS disk encryption key file in plain text either in `/crypto_keyfile.bin`, or in a CPIO archive attached to their NixOS initrd. `nixos-install` is not affected, nor are UEFI installations, nor was the default automatic partitioning configuration on legacy BIOS systems. The problem has been fixed in calamares-nixos-extensions 0.3.17, which was included in NixOS. The current installer images for the NixOS 24.05 and unstable (24.11) channels are unaffected. The fix reached 24.05 at 2024-08-13 20:06:59 UTC, and unstable at 2024-08-15 09:00:20 UTC. Installer images downloaded before those times may be vulnerable. The best solution for affected users is probably to back up their data and do a complete reinstallation. However, the mitigation procedure in GHSA-3rvf-24q2-24ww should work solely for the case where `/` is encrypted but `/boot` is not. If `/` is unencrypted, then the `/crypto_keyfile.bin` file will need to be deleted in addition to the remediation steps in the previous advisory. This issue is a partial regression of CVE-2023-36476 / GHSA-3rvf-24q2-24ww, which was more severe as it applied to the default configuration on BIOS systems.
CVE-2024-4425 2026-04-15 5.4 Medium
The access control in CemiPark software stores integration (e.g. FTP or SIP) credentials in plain-text. An attacker who gained unauthorized access to the device can retrieve clear text passwords used by the system.This issue affects CemiPark software: 4.5, 4.7, 5.03 and potentially others. The vendor refused to provide the specific range of affected products.
CVE-2024-45283 2026-04-15 6 Medium
SAP NetWeaver AS for Java allows an authorized attacker to obtain sensitive information. The attacker could obtain the username and password when creating an RFC destination. After successful exploitation, an attacker can read the sensitive information but cannot modify or delete the data.
CVE-2025-0936 2026-04-15 6.5 Medium
On affected platforms running Arista EOS with a gNMI transport enabled, running the gNOI File TransferToRemote RPC with credentials for a remote server may cause these remote-server credentials to be logged or accounted on the local EOS device or possibly on other remote accounting servers (i.e. TACACS, RADIUS, etc).
CVE-2025-7357 2026-04-15 N/A
LITEON IC48A firmware versions prior to 01.00.19r and LITEON IC80A firmware versions prior to 01.01.12e store FTP-server-access-credentials in cleartext in their system logs.
CVE-2025-3758 2026-04-15 N/A
WF2220 exposes endpoint /cgi-bin-igd/netcore_get.cgi that returns configuration of the device to unauthorized users. Returned configuration includes cleartext password. The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2024-25138 2026-04-15 6.5 Medium
In AutomationDirect C-MORE EA9 HMI, credentials used by the platform are stored as plain text on the device.
CVE-2024-27166 1 Toshibatec 50 E-studio-2010-ac, E-studio-2015-nc, E-studio-2018 A and 47 more 2026-04-15 7.4 High
Coredump binaries in Toshiba printers have incorrect permissions. A local attacker can steal confidential information. As for the affected products/models/versions, see the reference URL.
CVE-2024-28736 1 Debezium Community Project 1 Debezium-ui 2026-04-15 7.1 High
An issue in Debezium Community debezium-ui v.2.5 allows a local attacker to execute arbitrary code via the refresh page function.
CVE-2024-3624 1 Redhat 1 Mirror Registry 2026-04-15 7.3 High
A flaw was found in how Quay's database is stored in plain-text in mirror-registry on the jinja's config.yaml file. This flaw allows a malicious actor with access to this file to gain access to Quay's database.
CVE-2024-3625 1 Redhat 1 Mirror Registry 2026-04-15 7.3 High
A flaw was found in Quay, where Quay's database is stored in plain text in mirror-registry on Jinja's config.yaml file. This issue leaves the possibility of a malicious actor with access to this file to gain access to Quay's Redis instance.
CVE-2024-39220 1 Bas-ip 29 Aa-07bd, Aa-07bdi, Av-01bd and 26 more 2026-04-15 6.5 Medium
BAS-IP AV-01D, AV-01MD, AV-01MFD, AV-01ED, AV-01KD, AV-01BD, AV-01KBD, AV-02D, AV-02IDE, AV-02IDR, AV-02IPD, AV-02FDE, AV-02FDR, AV-03D, AV-03BD, AV-04AFD, AV-04ASD, AV-04FD, AV-04SD, AV-05FD, AV-05SD, AA-07BD, AA-07BDI, BA-04BD, BA-04MD, BA-08BD, BA-08MD, BA-12BD, BA-12MD, CR-02BD before firmware v3.9.2 allows authenticated attackers to read SIP account passwords via a crafted GET request.
CVE-2024-41336 2026-04-15 7.5 High
Draytek devices Vigor 165/166 prior to v4.2.6 , Vigor 2620/LTE200 prior to v3.9.8.8, Vigor 2860/2925 prior to v3.9.7, Vigor 2862/2926 prior to v3.9.9.4, Vigor 2133/2762/2832 prior to v3.9.8, Vigor 2135/2765/2766 prior to v4.4.5.1, Vigor 2865/2866/2927 prior to v4.4.5.3, Vigor 2962/3910 prior to v4.3.2.7, Vigor 3912 prior to v4.3.5.2, and Vigor 2925 up to v3.9.6 were discovered to store passwords in plaintext.
CVE-2024-43659 2026-04-15 7.2 High
After gaining access to the firmware of a charging station, a file at <redacted> can be accessed to obtain default credentials that are the same across all Iocharger AC model EV chargers. This issue affects Iocharger firmware for AC models before firmware version 25010801. The issue is addressed by requiring a mandatory password change on first login, it is still recommended to change the password on older models. Likelihood: Moderate – The attacker will first have to abuse a code execution or file inclusion vulnerability (for example by using <redacted>.sh) to gain access to the <redacted>.json file, or obtain a firmware dump of the charging station or obtain the firmware via other channels. Impact: Critical – All chargers using Iocharger firmware for AC models started with the same initial password. For models with firmware version before 25010801 a password change was not mandatory. It is therefore very likely that this firmware password is still active on many chargers. These credentials could, once obtained, allow an attacker to log into many Iocharger charging station, and allow them to execute arbitrary commands via the System → Custom page. CVSS clarification: Any network interface serving the web ui is vulnerable (AV:N) and there are not additional security measures to circumvent (AC:L), nor does the attack require and existing preconditions (AT:N). The attack is authenticated, and requires high privileges (PR:H), there is no user interaction required (UI:N). The attack leads to a compromised of the confidentialy of the "super user" credentials of the device (VC:H/VI:N/VA:N), and can subsequently be used to full compromise and other devices (SC:H/SI:H/SA:H). Becuase this is an EV charger handing significant power, there is a potential safety impact (S:P). This attack can be automated (AU:Y).
CVE-2025-11193 1 Lenovo 2 Tablet, Yoga 2026-04-15 5.5 Medium
A potential vulnerability was reported in some Lenovo Tablets that could allow a local authenticated user or application to gain access to sensitive device specific information.
CVE-2025-24375 2026-04-15 5 Medium
Charmed MySQL K8s operator is a Charmed Operator for running MySQL on Kubernetes. Before revision 221, the method for calling a SQL DDL or python based mysql-shell scripts can leak database users credentials. The method mysql-operator calls mysql-shell application rely on writing to a temporary script file containing the full URI, with user and password. The file can be read by a unprivileged user during the operator runtime, due it being created with read permissions (0x644). On other cases, when calling mysql cli, for one specific case when creating the operator users, the DDL contains said users credentials, which can be leak through the same mechanism of a temporary file. All versions prior to revision 221 for kubernetes and revision 338 for machine operators.