Search Results (415 CVEs found)

CVE Vendors Products Updated CVSS v3.1
CVE-2025-11743 1 Rockwellautomation 1 Compactlogix 5370 2026-04-15 N/A
A denial-of-service security issue in the affected product. The security issue occurs when a malformed CIP forward open message is sent. This could result in a major nonrecoverable fault a restart is required to recover.
CVE-2025-7350 1 Rockwellautomation 1 Stratix 2026-04-15 N/A
A security issue affecting multiple Cisco devices also directly impacts Stratix® 5410, 5700, and 8000 devices. This can lead to remote code execution by uploading and running malicious configurations without authentication.
CVE-2025-7353 1 Rockwellautomation 1 Controllogix 2026-04-15 N/A
A security issue exists due to the web-based debugger agent enabled on Rockwell Automation ControlLogix® Ethernet Modules. If a specific IP address is used to connect to the WDB agent, it can allow remote attackers to perform memory dumps, modify memory, and control execution flow.
CVE-2025-11084 1 Rockwellautomation 1 Factorytalk 2026-04-15 N/A
A security issue exists within DataMosaix™ Private Cloud, allowing attackers to bypass MFA during setup and obtain a valid login-token cookie without knowing the users password. This vulnerability occurs when MFA is enabled but not completed within a 7-day period.
CVE-2025-9177 1 Rockwellautomation 1 1715-aentr Ethernet/ip Adapter 2026-04-15 N/A
A denial-of-service security issue exists in the affected product and version. The security issue stems from a high number of requests sent to the web server. This could result in a web server crash however; this does not impact I/O control or communication . A power cycle is required to recover and utilize the webpage.
CVE-2025-9368 1 Rockwellautomation 1 432es-ig3 Series A 2026-04-15 N/A
A security issue exists within 432ES-IG3 Series A, which affects GuardLink® EtherNet/IP Interface, resulting in denial-of-service. A manual power cycle is required to recover the device.
CVE-2024-6078 1 Rockwellautomation 1 Datamosaix 2026-04-15 N/A
CVE-2024-6078 IMPACT An improper authentication vulnerability exists in the affected product, which could allow a malicious user to generate cookies for any user ID without the use of a username or password. If exploited, a malicious user could take over the account of a legitimate user. The malicious user would be able to view and modify data stored in the cloud.
CVE-2025-11697 1 Rockwellautomation 1 Studio 5000 Simulation Interface 2026-04-15 N/A
A local code execution security issue exists within Studio 5000® Simulation Interface™ via the API. This vulnerability allows any Windows user on the system to extract files using path traversal sequences, resulting in execution of scripts with Administrator privileges on system reboot.
CVE-2025-14376 1 Rockwellautomation 1 Verve Asset Manager 2026-04-15 N/A
A security issue was discovered within the legacy ADI server component of Verve Asset Manager, caused by plaintext secrets stored in environment variables on the ADI server. This component has been retired and has been optional since the 1.36 release in 2024.
CVE-2025-7973 1 Rockwellautomation 1 Factorytalk View 2026-04-15 N/A
A security issue exists in FactoryTalk ViewPoint version 14.0 or below due to improper handling of MSI repair operations. During a repair, attackers can hijack the cscript.exe console window, which runs with SYSTEM privileges. This can be exploited to spawn an elevated command prompt, enabling full privilege escalation.
CVE-2024-9412 1 Rockwellautomation 1 Verve Asset Manager 2026-04-15 N/A
An improper authorization vulnerability exists in the Rockwell Automation affected products that could allow an unauthorized user to sign in. While removal of all role mappings is unlikely, it could occur in the case of unexpected or accidental removal by the administrator. If exploited, an unauthorized user could access data they previously but should no longer have access to.
CVE-2025-11862 1 Rockwellautomation 1 Verve Asset Manager 2026-04-15 N/A
A security issue was discovered within Verve Asset Manager allowing unauthorized read-only users to read, update, and delete users via the API.
CVE-2025-9036 1 Rockwellautomation 1 Factorytalk Action Manager 2026-04-15 N/A
A security issue in the runtime event system allows unauthenticated connections to receive a reusable API token. This token is broadcasted over a WebSocket and can be intercepted by any local client listening on the connection.
CVE-2024-10945 1 Rockwellautomation 1 Factorytalk Updater 2026-04-15 7.3 High
A Local Privilege Escalation vulnerability exists in the affected product. The vulnerability requires a local, low privileged threat actor to replace certain files during update and exists due to a failure to perform proper security checks before installation.
CVE-2025-9437 1 Rockwellautomation 1 Armorstart Aop 2026-04-15 N/A
A security issue exists within the Studio 5000 Logix Designer add-on profile (AOP) for the ArmorStart Classic distributed motor controller, resulting in denial-of-service. This vulnerability is possible due to the input of invalid values into Component Object Model (COM) methods.
CVE-2025-9178 1 Rockwellautomation 1 1715-aentr Eternet/ip Adapter 2026-04-15 N/A
A denial-of-service security issue exists in the affected product and version. The security issue is caused through CIP communication using crafted payloads. The security issue could result in no CIP communication with 1715 EtherNet/IP Adapter.A restart is required to recover.
CVE-2025-9041 1 Rockwellautomation 1 Flex 5000 Io 2026-04-15 N/A
A security issue exists due to improper handling of CIP Class 32’s request when a module is inhibited on the 5094-IF8 device. It causes the module to enter a fault state with the Module LED flashing red. Upon un-inhibiting, the module returns a connection fault (Code 16#0010), and the module cannot recover without a power cycle.
CVE-2025-9042 1 Rockwellautomation 1 Flex 5000 Io 2026-04-15 N/A
A security issue exists due to improper handling of CIP Class 32’s request when a module is inhibited on the 5094-IY8 device. It causes the module to enter a fault state with the Module LED flashing red. Upon un-inhibiting, the module returns a connection fault (Code 16#0010), and the module cannot recover without a power cycle.
CVE-2025-13824 1 Rockwellautomation 3 Micro820, Micro850, Micro870 2026-04-15 N/A
A security issue exists due to improper handling of malformed CIP packets during fuzzing. The controller enters a hard fault with solid red Fault LED and becomes unresponsive. Upon power cycle, the controller will enter recoverable fault where the MS LED and Fault LED become flashing red and reports fault code 0xF019. To recover, clear the fault.
CVE-2025-7774 1 Rockwellautomation 1 Armorblock 5000 Io 2026-04-15 N/A
A security issue exists within the 5032 16pt Digital Configurable module’s web server. Intercepted session credentials can be used within a 3-minute timeout window, allowing unauthorized users to perform privileged actions.