Search Results (2547 CVEs found)

CVE Vendors Products Updated CVSS v3.1
CVE-2025-13252 1 Shsuishang 1 Shopsuite Modulithshop 2026-04-15 7.3 High
A vulnerability was found in shsuishang ShopSuite ModulithShop up to 45a99398cec3b7ad7ff9383694f0b53339f2d35a. Affected by this issue is some unknown functionality of the component RSA/OAuth2/Database. The manipulation results in hard-coded credentials. The attack can be executed remotely. The exploit has been made public and could be used. This product implements a rolling release for ongoing delivery, which means version information for affected or updated releases is unavailable.
CVE-2025-13221 1 Intelbras 1 Unniti 2026-04-15 5.3 Medium
A weakness has been identified in Intelbras UnniTI 24.07.11. The affected element is an unknown function of the file /xml/sistema/usuarios.xml. Executing manipulation of the argument Usuario/Senha can lead to unprotected storage of credentials. The attack can be executed remotely. The exploit has been made available to the public and could be exploited.
CVE-2025-11284 1 Zytec Dalian Zhuoyun Technology 1 Central Authentication Service 2026-04-15 7.3 High
A vulnerability has been found in Zytec Dalian Zhuoyun Technology Central Authentication Service 3. Affected by this vulnerability is an unknown functionality of the file /index.php/auth/Ops/git of the component HTTP Header Handler. The manipulation of the argument Authorization leads to use of hard-coded password. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2025-11193 1 Lenovo 2 Tablet, Yoga 2026-04-15 5.5 Medium
A potential vulnerability was reported in some Lenovo Tablets that could allow a local authenticated user or application to gain access to sensitive device specific information.
CVE-2025-0936 2026-04-15 6.5 Medium
On affected platforms running Arista EOS with a gNMI transport enabled, running the gNOI File TransferToRemote RPC with credentials for a remote server may cause these remote-server credentials to be logged or accounted on the local EOS device or possibly on other remote accounting servers (i.e. TACACS, RADIUS, etc).
CVE-2024-8774 2026-04-15 N/A
The SIMPLE.ERP client stores superuser password in a recoverable format, allowing any authenticated SIMPLE.ERP user to escalate privileges to a database administrator. This issue affect SIMPLE.ERP from 6.20 through 6.30. Only the 6.30 version received a patch 6.30@a03.9, which removed the vulnerability. Versions 6.20 and 6.25 remain unpatched.
CVE-2024-8767 1 Acronis 3 Backup Extension For Plesk, Backup Plugin For Cpanel \& Whm, Backup Plugin For Directadmin 2026-04-15 N/A
Sensitive data disclosure and manipulation due to unnecessary privileges assignment. The following products are affected: Acronis Backup plugin for cPanel & WHM (Linux) before build 619, Acronis Backup extension for Plesk (Linux) before build 555, Acronis Backup plugin for DirectAdmin (Linux) before build 147.
CVE-2024-8110 1 Yokogawa 1 Dual-redundant Platform For Computer \(pc2ckm\) 2026-04-15 7.5 High
Denial of Service (DoS) vulnerability has been found in Dual-redundant Platform for Computer. If a computer on which the affected product is installed receives a large number of UDP broadcast packets in a short period, occasionally that computer may restart. If both the active and standby computers are restarted at the same time, the functionality on that computer may be temporarily unavailable.
CVE-2024-6694 2026-04-15 2.7 Low
The WP Mail SMTP plugin for WordPress is vulnerable to information exposure in all versions up to, and including, 4.0.1. This is due to plugin providing the SMTP password in the SMTP Password field when viewing the settings. This makes it possible for authenticated attackers, with administrative-level access and above, to view the SMTP password for the supplied server. Although this would not be useful for attackers in most cases, if an administrator account becomes compromised this could be useful information to an attacker in a limited environment.
CVE-2024-52799 1 Argoproj 1 Argo-helm 2026-04-15 8.3 High
Argo Workflows Chart is used to set up argo and its needed dependencies through one command. Prior to 0.44.0, the workflow-role has excessive privileges, the worst being create pods/exec, which will allow kubectl exec into any Pod in the same namespace, i.e. arbitrary code execution within those Pods. If a user can be made to run a malicious template, their whole namespace can be compromised. This affects versions of the argo-workflows Chart that use appVersion: 3.4 and above, which no longer need these permissions for the only available Executor, Emissary. It could also affect users below 3.4 depending on their choice of Executor in those versions. This only affects the Helm Chart and not the upstream manifests. This vulnerability is fixed in 0.44.0.
CVE-2024-5275 1 Fortra 2 Filecatalyst Direct, Filecatalyst Workflow 2026-04-15 7.8 High
A hard-coded password in the FileCatalyst TransferAgent can be found which can be used to unlock the keystore from which contents may be read out, for example, the private key for certificates. Exploit of this vulnerability could lead to a machine-in-the-middle (MiTM) attack against users of the agent. This issue affects all versions of FileCatalyst Direct from 3.8.10 Build 138 and earlier and all versions of FileCatalyst Workflow from 5.1.6 Build 130 and earlier.
CVE-2024-4996 2026-04-15 9.8 Critical
Use of a hard-coded password for a database administrator account created during Wapro ERP installation allows an attacker to retrieve embedded sensitive data stored in the database. The password is same among all Wapro ERP installations. This issue affects Wapro ERP Desktop versions before 8.90.0.
CVE-2024-4425 2026-04-15 5.4 Medium
The access control in CemiPark software stores integration (e.g. FTP or SIP) credentials in plain-text. An attacker who gained unauthorized access to the device can retrieve clear text passwords used by the system.This issue affects CemiPark software: 4.5, 4.7, 5.03 and potentially others. The vendor refused to provide the specific range of affected products.
CVE-2024-43651 2026-04-15 N/A
Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability allows OS Command Injection as root This issue affects Iocharger firmware for AC models before version 241207101 Likelihood: Moderate – The <redacted> binary does not seem to be used by the web interface, so it might be more difficult to find. It seems to be largely the same binary as used by the Iocharger Pedestal charging station, however. The attacker will also need a (low privilege) account to gain access to the <redacted> binary, or convince a user with such access to execute a crafted HTTP request. Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and delete files and services. CVSS clarification: Any network connection serving the web interface is vulnerable (AV:N) and there are no additional measures to circumvent (AC:L) nor does the attack require special conditions to be present (AT:N). The attack requires authentication, but the level does not matter (PR:L), nor is user interaction required (UI:N). The attack leads to a full compromised (VC:H/VI:H/VA:H) and a compromised device can be used to potentially "pivot" into a network that should nopt be reachable (SC:L/SI:L/SA:H). Because this is an EV charger handing significant power, there is a potential safety impact (S:P). THe attack can be autometed (AU:Y).
CVE-2024-4232 2026-04-15 4.1 Medium
This vulnerability exists in Digisol Router (DG-GR1321: Hardware version 3.7L; Firmware version : v3.2.02) due to lack of encryption or hashing in storing of passwords within the router's firmware/ database. An attacker with physical access could exploit this by extracting the firmware and reverse engineer the binary data to access the plaintext passwords on the vulnerable system. Successful exploitation of this vulnerability could allow the attacker to gain unauthorized access to the targeted system.
CVE-2024-42197 1 Hcltech 1 Workload Scheduler 2026-04-15 5.5 Medium
HCL Workload Scheduler stores user credentials in plain text which can be read by a local user.
CVE-2024-41336 2026-04-15 7.5 High
Draytek devices Vigor 165/166 prior to v4.2.6 , Vigor 2620/LTE200 prior to v3.9.8.8, Vigor 2860/2925 prior to v3.9.7, Vigor 2862/2926 prior to v3.9.9.4, Vigor 2133/2762/2832 prior to v3.9.8, Vigor 2135/2765/2766 prior to v4.4.5.1, Vigor 2865/2866/2927 prior to v4.4.5.3, Vigor 2962/3910 prior to v4.3.2.7, Vigor 3912 prior to v4.3.5.2, and Vigor 2925 up to v3.9.6 were discovered to store passwords in plaintext.
CVE-2024-40116 1 Solar-log 1 Solar-log 1000 Firmware 2026-04-15 8.1 High
An issue in Solar-Log 1000 before v2.8.2 and build 52-23.04.2013 was discovered to store plaintext passwords in the export.html, email.html, and sms.html files -- fixed with 3.0.0-60 11.10.2013 for SL 200, 500, 1000 / not existing for SL 250, 300, 1200, 2000, SL 50 Gateway, SL Base.
CVE-2024-39922 2026-04-15 4.6 Medium
A vulnerability has been identified in LOGO! 12/24RCE (6ED1052-1MD08-0BA1) (All versions), LOGO! 12/24RCEo (6ED1052-2MD08-0BA1) (All versions), LOGO! 230RCE (6ED1052-1FB08-0BA1) (All versions), LOGO! 230RCEo (6ED1052-2FB08-0BA1) (All versions), LOGO! 24CE (6ED1052-1CC08-0BA1) (All versions), LOGO! 24CEo (6ED1052-2CC08-0BA1) (All versions), LOGO! 24RCE (6ED1052-1HB08-0BA1) (All versions), LOGO! 24RCEo (6ED1052-2HB08-0BA1) (All versions), SIPLUS LOGO! 12/24RCE (6AG1052-1MD08-7BA1) (All versions), SIPLUS LOGO! 12/24RCEo (6AG1052-2MD08-7BA1) (All versions), SIPLUS LOGO! 230RCE (6AG1052-1FB08-7BA1) (All versions), SIPLUS LOGO! 230RCEo (6AG1052-2FB08-7BA1) (All versions), SIPLUS LOGO! 24CE (6AG1052-1CC08-7BA1) (All versions), SIPLUS LOGO! 24CEo (6AG1052-2CC08-7BA1) (All versions), SIPLUS LOGO! 24RCE (6AG1052-1HB08-7BA1) (All versions), SIPLUS LOGO! 24RCEo (6AG1052-2HB08-7BA1) (All versions). Affected devices store user passwords in plaintext without proper protection. This could allow a physical attacker to retrieve them from the embedded storage ICs.
CVE-2024-38427 1 Color 1 Demoiccmax 2026-04-15 8.8 High
In International Color Consortium DemoIccMAX before 85ce74e, a logic flaw in CIccTagXmlProfileSequenceId::ParseXml in IccXML/IccLibXML/IccTagXml.cpp results in unconditionally returning false.