Export limit exceeded: 418271 CVEs match your query. Please refine your search to export 10,000 CVEs or fewer.
Search
Search Results (4374 CVEs found)
| CVE | Vendors | Products | Updated | CVSS v3.1 |
|---|---|---|---|---|
| CVE-2014-125124 | 3 Artica, Pandora Fms, Pandorafms | 4 Pandora Fms, Pandora Fms, Artica Pandora Fms and 1 more | 2026-04-15 | N/A |
| An unauthenticated remote command execution vulnerability exists in Pandora FMS versions up to and including 5.0RC1 via the Anyterm web interface, which listens on TCP port 8023. The anyterm-module endpoint accepts unsanitized user input via the p parameter and directly injects it into a shell command, allowing arbitrary command execution as the pandora user. In certain versions (notably 4.1 and 5.0RC1), the pandora user can elevate privileges to root without a password using a chain involving the artica user account. This account is typically installed without a password and is configured to run sudo without authentication. Therefore, full system compromise is possible without any credentials. | ||||
| CVE-2020-37123 | 1 Wcchandler | 1 Pinger | 2026-04-15 | 9.8 Critical |
| Pinger 1.0 contains a remote code execution vulnerability that allows attackers to inject shell commands through the ping and socket parameters. Attackers can exploit the unsanitized input in ping.php to write arbitrary PHP files and execute system commands by appending shell metacharacters. | ||||
| CVE-2024-54092 | 2026-04-15 | 9.8 Critical | ||
| A vulnerability has been identified in Industrial Edge Device Kit - arm64 V1.17 (All versions), Industrial Edge Device Kit - arm64 V1.18 (All versions), Industrial Edge Device Kit - arm64 V1.19 (All versions), Industrial Edge Device Kit - arm64 V1.20 (All versions < V1.20.2-1), Industrial Edge Device Kit - arm64 V1.21 (All versions < V1.21.1-1), Industrial Edge Device Kit - x86-64 V1.17 (All versions), Industrial Edge Device Kit - x86-64 V1.18 (All versions), Industrial Edge Device Kit - x86-64 V1.19 (All versions), Industrial Edge Device Kit - x86-64 V1.20 (All versions < V1.20.2-1), Industrial Edge Device Kit - x86-64 V1.21 (All versions < V1.21.1-1), Industrial Edge Own Device (IEOD) (All versions < V1.21.1-1-a), Industrial Edge Virtual Device (All versions < V1.21.1-1-a), SCALANCE LPE9413 (6GK5998-3GS01-2AC2) (All versions < V2.1), SIMATIC IPC BX-39A Industrial Edge Device (All versions < V3.0), SIMATIC IPC BX-59A Industrial Edge Device (All versions < V3.0), SIMATIC IPC127E Industrial Edge Device (All versions < V3.0), SIMATIC IPC227E Industrial Edge Device (All versions < V3.0), SIMATIC IPC427E Industrial Edge Device (All versions < V3.0), SIMATIC IPC847E Industrial Edge Device (All versions < V3.0). Affected devices do not properly enforce user authentication on specific API endpoints when identity federation is used. This could facilitate an unauthenticated remote attacker to circumvent authentication and impersonate a legitimate user. Successful exploitation requires that identity federation is currently or has previously been used and the attacker has learned the identity of a legitimate user. | ||||
| CVE-2025-9265 | 1 Kiloview | 1 Ndi N30 | 2026-04-15 | N/A |
| A broken authorization vulnerability in Kiloview NDI N30 allows a remote unauthenticated attacker to deactivate user verification, giving them access to state changing actions that should only be initiated by administratorsThis issue affects Kiloview NDI N30 and was fixed in Firmware version later than 2.02.0246 | ||||
| CVE-2025-9313 | 1 Mmedica | 1 Mmedica | 2026-04-15 | N/A |
| An unauthenticated user can connect to a publicly accessible database using arbitrary credentials. The system grants full access to the database by leveraging a previously authenticated connection through a "mmBackup" application. This flaw allows attackers to bypass authentication mechanisms and gain unauthorized access to database with sensitive data. This issue affects Asseco mMedica in versions before 11.9.5. | ||||
| CVE-2025-9963 | 1 Novakon | 1 P Series | 2026-04-15 | N/A |
| A path traversal vulnerability in Novakon P series allows to expose the root file system "/" and modify all files with root permissions. This way the system can also be compromized.This issue affects P series: P – V2001.A.C518o2 until P-2.0.05 Build 2026.02.06 (commit d0f97fd9). | ||||
| CVE-2025-9574 | 1 Abb | 2 Als-mini-s4, Als-mini-s8 | 2026-04-15 | 10 Critical |
| Missing Authentication for Critical Function vulnerability in ABB ALS-mini-s4 IP, ABB ALS-mini-s8 IP.This issue affects . All firmware versions with the Serial Number from 2000 to 5166 | ||||
| CVE-2025-9696 | 1 Sunpower | 1 Pvs6 | 2026-04-15 | N/A |
| The SunPower PVS6's BluetoothLE interface is vulnerable due to its use of hardcoded encryption parameters and publicly accessible protocol details. An attacker within Bluetooth range could exploit this vulnerability to gain full access to the device's servicing interface. This access allows the attacker to perform actions such as firmware replacement, disabling power production, modifying grid settings, creating SSH tunnels, altering firewall settings, and manipulating connected devices. | ||||
| CVE-2025-9965 | 1 Novakon | 1 P Series | 2026-04-15 | N/A |
| Improper authentication vulnerability in Novakon P series allows unauthenticated attackers to upload and download any application from/to the device.This issue affects P series: P – V2001.A.C518o2 until P-2.0.05 Build 2026.02.06 (commit d0f97fd9). | ||||
| CVE-2025-9972 | 2 N-partner, Planet | 4 N-cloud, N-probe, N-reporter and 1 more | 2026-04-15 | 9.8 Critical |
| Certain models of Industrial Cellular Gateway developed by Planet Technology have an OS Command Injection vulnerability, allowing unauthenticated remote attackers to inject arbitrary OS commands and execute them on the device. | ||||
| CVE-2009-20009 | 1 Belkin | 1 Bulldog Plus | 2026-04-15 | N/A |
| Belkin Bulldog Plus version 4.0.2 build 1219 contains a stack-based buffer overflow vulnerability in its web service authentication handler. When a specially crafted HTTP request is sent with an oversized Authorization header, the application fails to properly validate the input length before copying it into a fixed-size buffer, resulting in memory corruption and potential remote code execution. Exploitation requires network access and does not require prior authentication. | ||||
| CVE-2009-20010 | 2026-04-15 | N/A | ||
| Dogfood CRM version 2.0.10 contains a remote command execution vulnerability in the spell.php script used by its mail subsystem. The vulnerability arises from unsanitized user input passed via a POST request to the data parameter, which is processed by the underlying shell without adequate escaping. This allows attackers to inject arbitrary shell commands and execute them on the server. The flaw is exploitable without authentication and was discovered by researcher LSO. | ||||
| CVE-2010-10016 | 1 Bsplayer | 1 Bs.player | 2026-04-15 | N/A |
| BS.Player version 2.57 (build 1051) contains a vulnerability in its playlist import functionality. When processing .m3u files, the application fails to properly validate the length of playlist entries, resulting in a buffer overflow condition. This flaw occurs during parsing of long URLs embedded in the playlist, allowing overwrite of Structured Exception Handler (SEH) records. The vulnerability is triggered upon opening a crafted playlist file and affects the Unicode parsing logic in the Windows client. | ||||
| CVE-2011-10032 | 2 Microsoft, Sunwayland | 2 Windows, Forcecontrol | 2026-04-15 | N/A |
| Sunway ForceControl version 6.1 SP3 and earlier contains a stack-based buffer overflow vulnerability in the SNMP NetDBServer service, which listens on TCP port 2001. The flaw is triggered when the service receives a specially crafted packet using opcode 0x57 with an overly long payload. Due to improper bounds checking during packet parsing, attacker-controlled data overwrites the Structured Exception Handler (SEH), allowing arbitrary code execution in the context of the service. This vulnerability can be exploited remotely without authentication and may lead to full system compromise on affected Windows hosts. | ||||
| CVE-2025-0520 | 1 Showdoc | 1 Showdoc | 2026-04-15 | N/A |
| An unrestricted file upload vulnerability in ShowDoc caused by improper validation of file extension allows execution of arbitrary PHP, leading to remote code execution.This issue affects ShowDoc: before 2.8.7. | ||||
| CVE-2025-34044 | 2026-04-15 | N/A | ||
| A remote command injection vulnerability exists in the confirm.php interface of the WIFISKY 7-layer Flow Control Router via a specially-crafted HTTP GET request to the t parameter. Insufficient input validation allows unauthenticated attackers to execute arbitrary OS commands. Exploitation evidence was observed by the Shadowserver Foundation on 2025-01-25 UTC. | ||||
| CVE-2025-9118 | 1 Google | 1 Cloud Platform | 2026-04-15 | N/A |
| A path traversal vulnerability in the NPM package installation process of Google Cloud Dataform allows a remote attacker to read and write files in other customers' repositories via a maliciously crafted package.json file. | ||||
| CVE-2025-7964 | 1 Silabs | 1 Zigbee Stack | 2026-04-15 | N/A |
| After receiving a malformed 802.15.4 MAC Data Request the Zigbee Coordinator sends a ‘network leave’ request to Zigbee router resulting in the Zigbee Router getting stuck in a non-rejoinable state. If a suitable parent is not available, the end devices will be unable to rejoin. A manual recommissioning is required to recover the Zigbee Router. | ||||
| CVE-2025-8070 | 1 Asustor | 2 Abp, Aes | 2026-04-15 | N/A |
| The Windows service configuration of ABP and AES contains an unquoted ImagePath registry value vulnerability. This allows a local attacker to execute arbitrary code by placing a malicious executable in a predictable location such as C:\Program.exe. If the service runs with elevated privileges, exploitation results in privilege escalation to SYSTEM level. This vulnerability arises from an unquoted service path affecting systems where the executable resides in a path containing spaces. Affected products and versions include: ABP 2.0.7.6130 and earlier as well as AES 1.0.6.6133 and earlier. | ||||
| CVE-2025-8284 | 1 Packet Power | 2 Eg, Emx | 2026-04-15 | 9.8 Critical |
| By default, the Packet Power Monitoring and Control Web Interface do not enforce authentication mechanisms. This vulnerability could allow unauthorized users to access and manipulate monitoring and control functions. | ||||